Product Detail
VSD*HL-*-KD2
Quick Overview
HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF
Mounting Surfaces: NFPA D03 to D10
Max Pressure: 5000 PSI (350 bar)Max Flow Rates: 40 to 290 gpm (151 to 1098 l/min)
The VSD*HL solenoid operated directional control valves are in compliance with ATEX 94/9/EC standards. They are suitable for use in potentially explosive atmospheres which fall within the ATEX II 2GD classification for gas and dust.
These valves are available in both direct operated and pilot operated models in the following sizes:
DIRECT OPERATED: NFPA D03 (ISO 4401-03)
NFPA D05 (ISO 4401-05)
PILOT OPERATED: NFPA D05 alt. A/alt. B (ISO 4401-05-05-0-05)
NFPA D07 (ISO 4401-07-07-0-05)
NFPA D08 (ISO 4401-08-08-0-05)
NFPA D10 (ISO 4401-10-09-0-05)
The VSD*HL valve is supplied with a Zinc-Nickel surface treatment to ensure a salt spray resistance of up to 370 h. (test conducted per UNI EN ISO 9227 and evaluated per UNI EN ISO 10289). The Zinc-Nickel surface treatment is available on the pilot operated valves upon request.
A statement of conformity to the applicable standards is supplied with each valve.
The label and electrical box on these valves have a concentration of magnesium lower than the critical value of 7.5% for the Hazardous Environments.
Specifications |
||||
Max Pressure
|
P-A-B Ports |
D03 D07 D08 D10 |
5000 psi |
350 bar |
D05 D05A D05B |
4600 psi |
210 psi |
||
T Port (external drain) |
D05A D05B D07 D08 D10 |
3000 psi |
210 bar |
|
T Port (internal drain) |
D03 D05 |
3000 psi |
210 bar |
|
D05A D05B D07 D08 D10 |
2000 psi |
140 bar |
||
Pilot Pressure
|
Minimum |
D05A D05B |
72 to 145 psi |
5 to 10 bar |
D07 |
72 to 175 psi |
5 to 12 bar |
||
D08 |
102 to 204 psi |
7 to 14 bar |
||
D10 |
87 to 175 psi |
6 to 12 bar |
||
Maximum |
D05A D05B D07 D08 D10 |
3000 psi |
210 bar |
|
Max Flow Rate |
D03 |
20 gpm |
76 l/min |
|
D05 |
33 gpm |
125 l/min |
||
D05A D05B |
40 gpm |
150 l/min |
||
D07 |
80 gpm |
300 l/min |
||
D08 |
160 gpm |
600 l/min |
||
D10 |
290 gpm |
1100 l/min |
||
Mounting Standards |
D03 |
NFPA D03 ISO 4401-03-02-0-03 |
||
D05 |
NFPA D05 ISO 4401-05-04-0-05 |
|||
D05A D05B |
NFPA D05 alt. A/alt. B ISO 4401-05-05-0-05 |
|||
D07 |
NFPA D07 ISO 4401-07-07-0-05 |
|||
D08 |
NFPA D08 ISO 4401-08-08-0-05 |
|||
D10 |
NFPA D10 ISO 4401-10-09-0-05 |