SOLENOID AIR PILOT ACTUATED VALVE
Pilot Pressure Range: 35 to 100 PSI (2.5 to 7 bar)Operating Pressure Range: 28 inHg Vacuum to 150 PSI (711.2 mmHg Vacuum to 10 bar)
Flow Capacity: 3.85 to 11.5 SCFM (100 to 246 NLPM)
Numatics 2002 Series is made up of three individual series the F2, 02, and R2 series. The F2 series is distinguished by the rubber packed spool without a body to base plug, whereas the R2 series has a rubber packed spool bu also the body base plug. The 02 series is identified by a spool/sleeve with a body to base plug.
F2 Series
- Individual base mount
- Hardwired manifold mount
- 5 ported, 2 and 3 position, 4-way and dual 3-way, packed spool
- Cv – 0.25
- Low current requirements
- Elimination of internal wiring
- Buna-N seals provide leak-proof sealing
- Pusher piston – high spool shifting force
- Adjustable port sizes utilizing interchangeable cartridge fittings
02 Series
- 5 ported, 2 and 3 position, 4-way, spool & sleeve
- Cv – 0.20
- Solenoid air pilot actuated
- Low current requirements
- Elimination of internal wiring
- Pusher piston – high spool shifting force
- Modular fieldbus electronics and I/O
- Adjustable port sizes utilizing interchangeable cartridge fittings
R2 Series
- 5 ported, 2 and 3 position, 4-way and dual 3-way, packed spool
- Cv – 0.25 (4-way), 0.20 (dual 3-way)
- Solenoid air pilot actuated
- Low current requirements
- Elimination of internal wiring
- Buna-N seals provide leak-proof sealing
- Pusher piston – high spool shifting force
- Modular fieldbus electronics and I/O
- Adjustable port sizes utilizing interchangeable cartridge fittings
F2 Series | |||
Flow Capacity | 11.5 SCFM | 246 NLPM | |
Pilot Pressure Range | 35 to 100 PSI | 2.5 to 7 bar | |
Operating Pressure Range | 4-way | 28" Hg Vacuum to 150 PSI | 711.2 mm Hg Vacuum to 10 bar |
Dual 3-way | 0 to 100 PSI | 0 to 7 bar | |
Ambient Temperature Range | -10 to +115 °F | -23 to +46 °C |
02 Series | |||
Flow Capacity | 9.2 SCFM | 197 NLPM | |
Pilot Pressure Range | 35 to 100 PSI | 2.5 to 7 bar | |
Operating Pressure Range | 4-way | 28" Hg Vacuum to 150 PSI | 711.2 mm Hg Vacuum to 10 bar |
Dual 3-way | 28" Hg Vacuum to 150 PSI | 711.2 mm Hg Vacuum to 10 bar | |
Ambient Temperature Range | -10 to +115 °F | -23 to +46 °C |
R2 Series | |||
Flow Capacity | 3.85 SCFM | 100 NLPM | |
Pilot Pressure Range | 35 to 100 PSI | 2.5 to 7 bar | |
Operating Pressure Range | 4-way | 28" Hg Vacuum to 100 PSI | 711.2 mm Hg Vacuum to 7 bar |
Dual 3-way | 0 to 100 PSI | 0 to 7 bar | |
Ambient Temperature Range | -10 to +115 °F | -23 to +46 °C |