HSPC

Quick Overview

PILOT OPERATED CHECK VALVE

Max Pressure: 5000 PSI (345 bar)
Max Flow Rate: 22 to 120 gpm (83 to 455 l/min)

The HSPC cartridge type check valve allows free flow in one direction but prevents flow in the other until sufficient pressure is applied at the pilot port.

Pressure at port 2 forces the check ball off the seat and compresses the spring to allow flow to port 1. Reverse flow pressure (from port 1) forces the ball against the seat to stop flow. However, when sufficient pressure is piloted to port 3, it will shift the larger area spool and in turn move the ball off its seat to allow reverse flow from port 1 to port 2.

Pilot pressure must be sufficient to overcome the force generated by the pressure at port 1 and the spring.

The valve is constructed of steel parts, all operating parts are hardened. The cartridge is designed for easy service or field repair.

800 1200 1600
Pilot Pressure Ratio 4 : 1 10 : 1 3 : 1 3 : 1
Max Flow (Δ 100 psi/7 bar) 22 gpm 83 l/min 7 gpm 271 l/min 65 gpm 246 l/min 120 gpm 455 l/min
Max Operating Pressure 5000 psi 345 bar 5000 psi 345 bar 5000 psi 345 bar 5000 psi 345 bar
Cracking Pressure 10 psi 0.7 bar 25 psi 1.7 bar 10 psi 0.7 bar 8 psi 0.5 bar
Viscosity Range 27 to 2000 SSU at 100 °F
Temperature Range -40 to +350 °F -40 to +175 °C

Product Specifications