EDF*M

Quick Overview

COMPENSATED PROPORTIONAL FLOW CONTROL VALVE

Mounting Surface: NFPA D03, D05

Max Pressure: 3600 PSI (250 bar)
Rated Flow Rate: 3.7 to 21 gpm (14 to 80 l/min)

EDF03M and EDF05M are direct operated normally closed proportional flow control valves with pressure compensation.

These valves are subplate mounted according to NFPA/T.3.5.1 R2-2002 and ISO 4401:2005 standards. These valves are used to regulate flow in a hydraulic circuit. Output flow is directly proportional to the input current to the solenoid.

The EDF valves can be used as either a restrictive (2 way) or bypass (3 way) flow control.

Restrictive compensators are typically used in circuits supplied by variable volume pumps. Block ‘P’ port of the subplate to use the valve as a restrictive compensator flow control.

Bypass compensators are typically used in circuits with fixed volume pumps. Connect ‘P’ port to the tank to use the valve as a bypass flow control.

T port in the manifold must always be plugged.

D03 D05
Rated Flow Rate EDF03M-14 3.7 gpm 14 l/min - -
EDF03M-30 8 gpm 30 l/min - -
EDF03M-20 5.3 gpm 20 l/min - -
EDF03M-40 10.5 gpm 40 l/min - -
EDF05M-80 - - 21 gpm 80 l/min
Max Operating Pressure All Ports 3600 psi 250 bar
Min Pressure Drop A to B EDF03M-14 58 psi 4 bar - -
EDF03M-30 - -
EDF03M-20 116 psi 8 bar - -
EDF03M-40 - -
EDF05M-80 - - 116 psi 8 bar
Compensator Spring EDF03M-14 145 psi 10 bar - -
EDF03M-30 - -
EDF03M-20 320 psi 22 bar - -
EDF03M-40 - -
EDF05M-80 - - 320 psi 22 bar
Viscosity Range 60 to 1900 SSU at 100 °F 10  to 400 cSt
Temperature Range -4 to +176 °F -20 to +80 °C

Product Specifications